Email:frank.engineer11@gmail.com

聯絡地址:102 moo.2 T.changkong A.Nanoi Nan 55150 Thailand

Novec-1230 Design(圖1)-速報App

Novec-1230, fluid is an environmentally friendly Halon replacement for use as a gaseous fire suppression agent. Novec-1230 is manufactured. It is generally used in situations where water from a fire sprinkler would damage expensive equipment or where water-based fire protection is impractical, such as museums, banks, clean rooms and hospitals. Novec -1230 fluid does not deplete ozone (ODP 0).

Novec-1230 Fire Protection Fluid is a next-generation holan alternative offering outstanding performance, large margin of safety and excellent environmental profile

Novec-1230 Design(圖2)-速報App

• Zero ozone depletion potential

• A global warning potential of 1

Novec-1230 Design(圖3)-速報App

• 5-day atmospheric lifetime

• A large margin of safety for occupied spaces

Novec-1230 Design(圖4)-速報App

Novec-1230 Fire Protection Fluid is Based on a proprietary chemical A fluorketone. The full chemical name for this compound is dodecafluoro-2-methylpentan-3-one. Its ASHRAE nomenclature-the way it is designaed in the NFPA 2001 and ISO 14520 clean agent standars-is FK-5-1-12. Novec-1230 Fluid offers a unique combination of safety, low environmental impact and extinguishing performance,making it the first chemical halon replacement to offer a viable, long-term,sustainable technology for special hazards fire protection.

Download Manual Novec-1230 Desing Link

Novec-1230 Design(圖5)-速報App

https://drive.google.com/file/d/0BxaWWGlfYY6NVmtSU0ctZ0djdTg/view?usp=sharing

Function in Novec-1230 Design

Novec-1230 Design(圖6)-速報App

1. Calculation Room Volume For Design Room

2. Function Data Design Class concentration

Novec-1230 Design(圖7)-速報App

3. Calculation Novec-1230

4. Calculation Number Nozzle Novec-1230 For design Pipe

Novec-1230 Design(圖8)-速報App

5. Calculation design Pipe For

6. Table design Pipe Novec-1230

Novec-1230 Fluid is Applied as a gas, but is liquid at room temperature. It is electrically non-conducting in both the liquid and gasesous state. The breakdown voltage of Novec-1230 fluid vapor ubder saturated conditions at 1 atm ,21 C over a 2.7 mm electrode gap is 15.6 kV, nearly 2.3 time that of dry nitrogen. The breakdown voltage of liquid Novec-1230 fluid under the same conditions is 48 kV.The properties of Novec-1230 are similar to many of the firest generation halon alternatives with one primary exception –this compound is a liquid at ambient conditions. The boiling point of Novec-1230 fluid is 49.2 C , meaning this product has a much lower vapor pressure than other clean agents, which are gases at ambient conditions.Novec-1230 fluid has a very low heat of vaporization, approximately 25 times less then that of water. This allows the agent to transition from a liquid to a gaseous state very rapidly when discharged through a nozzle. In a properly designed system, Novec-1230 fluid will rapidly vaporize and evenly distribute throughout the protected space.